Sign In | Join Free | My himfr.com
Home > Atomic Absorption Spectrometer >

8 Lampshade Flame System Spectrophotometer Aas For Heavy Metals Elements

    Buy cheap 8 Lampshade Flame System Spectrophotometer Aas For Heavy Metals Elements from wholesalers
     
    Buy cheap 8 Lampshade Flame System Spectrophotometer Aas For Heavy Metals Elements from wholesalers
    • Buy cheap 8 Lampshade Flame System Spectrophotometer Aas For Heavy Metals Elements from wholesalers
    • Buy cheap 8 Lampshade Flame System Spectrophotometer Aas For Heavy Metals Elements from wholesalers

    8 Lampshade Flame System Spectrophotometer Aas For Heavy Metals Elements

    Ask Lasest Price
    Brand Name : Macylab
    Model Number : AA-1800DL
    Certification : CE ISO ROHS FCC FAD
    Price : USD16376-USD24558/Set
    Payment Terms : Western Union, MoneyGram, T/T, L/C
    Supply Ability : 5000Set / year
    Delivery Time : 5-10days
    • Product Details
    • Company Profile

    8 Lampshade Flame System Spectrophotometer Aas For Heavy Metals Elements



    AA-1800DL Atomic Absorption Spectrophotometer

    AA-1800DL atomic absorption spectrophotometer is absorted the latest international technology and famous universities jointly complete R & D, application experience with decades of spectral instrument. The products include the flame , graphite furnace and hydride generation system, can be equipped with various accessories, flexible configuration program can meet different customer demand. AA-1800 atomic absorption spectrometer can be used for analysis of complex samples ,full automatic multifunctional, various analysis methods can automatically switch, unmanned automatic analysis.
    AA-1800DL atomic absorption spectrophotometer is now widely used in scientific research,quality control, disease control, environmental protection, metallurgy, agriculture,chemical industry .Hardware and software design of innovation to ensure the accuracy,safety, ease of use in the analysis of samples, equipment maintenance, simple and convenient.


    Main features


    High precision automatic optical system
    1800 / mm reticle (dispersion rate) large area grating monochromator, a new type self collimation, all lenses are quartz coating, the detection range and the stability of optical broad to ensure the precision of analysis. Automatic 8 socket configuration 8 independent lamp power supply, can be respectively preheating

    Polymer spray chamber
    Polymer materials corrosion spray chamber, acid and alkali resistance, includinghydrofluoric acid, either organic or inorganic solution can be the highest sensitivity andstability

    Titanium burner
    Titanium burner, the optional 50mm and 100mm burner, air cooling pre mixed type,corrosion resistant, resistant to high salt, greatly improve the analysis efficiency andaccuracy of the flame

    Automatic analysis
    It can automatically accomplish safety ignition, extinction and switching, reliable structure,low fault rate, thus ensuring the sensitivity and reproducibility of the flame method.
    The light source system 8 lamp automatic conversion, can be directly used high performance hollow cathode lamp, improve the sensitivity analysis of the flame, the automatic adjustment of the power supply parameters and the beam position, automaticwavelength scanning and searching peak


    Software function
    High intelligent software, powerful function, friendly interface English operation.Automatic instruments and additional control, flame, graphite furnace operating mode can be switched automatically, automatic optimization, automatic dilution; mouse operation, automatic setup menu data and correction method



    Technical parameters

    Mainframe

    Light Source

    ≤8 lamps automatic turret, automatic alignment

    Power Supply

    110/220V (+5% ~ -10%), 60/50Hz; 5000VA

    Lamp Current

    pulsed power supply

    Optical System

    large 1800 /mm grating ruling, full closed optical system

    Wavelength Range

    185nm-900nm Automatically peak find,a key opticaloptimization function

    Wavelength Accuracy

    ±0.15nm

    Wavelength Repeatability

    <0.1nm

    Spectral Bandwidth

    0.1,0.2,0.4,0.7,1.0,1.4,2.0nm (7 steps with automatic changeover)

    Baseline Stability

    ≤±0.002A/30 min (Static) ≤±0.004A/30min (Dynamic)

    Absorbance Range

    0-4A


    Flame Analytical System

    Detector

    imported photomultiplier tube

    Burner Head

    full titanium combustion head, 50mm or 100mm generalcombustion head

    Atomization Chamber

    polymer explosion-proof spray chamber

    Nebulizer

    atomizer efficient glass atomizer, can also be customized

    Ignition Type

    microcomputer control, automatic ignition

    Gas Control

    automatic gas control system

    Detection Limits(Cu)

    0.002μg/mL

    Precision

    RSD≤0.5%






    Application Field