Sign In | Join Free | My himfr.com
Home > Laboratory Spectrophotometer >

Macy Lab Cid Detector Faster Detection Speed Medium Step Grating ICP-6810

    Buy cheap Macy Lab Cid Detector Faster Detection Speed Medium Step Grating ICP-6810 from wholesalers
     
    Buy cheap Macy Lab Cid Detector Faster Detection Speed Medium Step Grating ICP-6810 from wholesalers
    • Buy cheap Macy Lab Cid Detector Faster Detection Speed Medium Step Grating ICP-6810 from wholesalers

    Macy Lab Cid Detector Faster Detection Speed Medium Step Grating ICP-6810

    Ask Lasest Price
    Brand Name : Macylab
    Model Number : ICP6810
    Certification : ALL OF MADE IN CHINA
    Price : TALK ABOUT IT
    Payment Terms : L/C, T/T, Western Union, MoneyGram
    Supply Ability : 120SET/DAY
    Delivery Time : Within 5 days
    • Product Details
    • Company Profile

    Macy Lab Cid Detector Faster Detection Speed Medium Step Grating ICP-6810

    ICP6810 in the nonferrous gold industry

    The ICP6810 profile is introduced

    ICP-6810 is Full spectrum direct reading inductively coupled plasma emission spectrometer for determining trace and trace element content in different substances (soluble in nitric acid, hydrochloric acid, hydrofluoric acid, etc.), which is widely used in environmental protection, petroleum products, rare earths, semiconductors, geology, metallurgy, chemical industry, clinical medicine, food, biological samples, criminal science, agricultural research and other fields.


    Table 1. Main technical parameters of ICP6810

    ICP6810 main technical parameters

    High frequency ionizer

    Working frequency 27.12MHz

    Frequency stability ﹤0.05%

    Output power 800W ~1600W

    Output power stability ≤0.05%

    OMatching way Automatic matching

    Scan the light divider

    light path Full reflection imaging light path, quartz prism two-dimensional dispersion system

    focal distance 400mm

    Graster specifications Middle step grating, 52.67, l p / mm, 64 shining angle

    Resolution ratio <0.0068nm@200nm

    Complete machine technical indicators

    Scan the wavelength range At 165-900nm, full wavelength coverage, and measurable Al 167.120nm

    Repetitiveness RSD≤1.5%

    Stability RSD≤2.0%


    ICP6810 element detection limit (g / L)

    elementLaCePrNdSmEuGdTb
    wavelength (nm)408.672413.765414.311401.225360.946381.967342.247350.917
    detection limit<3.0<5.0<5.0<5.0<10.0<1.0<10.0<3.0

    elementDyHoErTmYbLuYSc
    wavelength (nm)353.170345.600337.271313.126369.419261.541371.030335.373
    detection limit<3.0<3.0<3.0<3.0<1.0<3.0<1.0<1.0

    elementTaNbMnMgBZnCoSi
    wavelength (nm)226.230313.340257.610279.553249.773213.856228.616251.611
    detection limit<5.0<5.0<3.0<1.0<10.0<3.0<3.0<10.0

    elementNiCdFeCaMoVBeTi
    wavelength (nm)232.003226.502239.562393.366281.615310.230313.041334.941
    detection limit<5.0<3.0<3.0<1.0<5.0<5.0<1.0<3.0

    elementCuCrAlZrAgSrAuPt
    wavelength (nm)324.754267.716396.152343.823328.068407.771242.795265.945
    detection limit<3.0<5.0<5.0<5.0<3.0<1.0<5.0<5.0

    elementPdIrRhRuBaLiNaK
    wavelength (nm)340.458224.268343.489240.272455.403670.784588.995766.490
    detection limit<5.0<10.0<10.0<5.0<1.0≤3≤20≤60

    elementAsSbBiHgPbGaOsW
    wavelength (nm)228.812206.833223.061253.652220.353294.364225.585207.911
    detection limit≤15≤15≤10≤15≤15≤10≤1≤10

    elementSnTeTaThTlReGeSe
    wavelength (nm)242.949214.281226.230283.730276.787227.525209.426203.985
    detection limit≤20≤10≤5.0≤10≤30≤5≤15≤30

    2. Precious metal sample test solution

    sample measureelement Analysis instrument Sample handling overview (for reference only) remarks

    Non-ferrous precious metal alloy Gold, silver, palladium, platinum, and so on ICP6810 Take 0.1-0.3g sample in a 100ml beaker, add 5ml hydrochloric acid, dissolve the sample on the heating plate to clarification, remove cold to room temperature, transferred to 50ml volumetric flask diluted with water to scale for testing. Sample blank experiment was also performed simultaneously duringthesampleprocessing process.



    According to the configured standard solution concentration, directly on the computer test, the instrument can automatically give the final test results, and can be directly printed in the form of a report.

    Table 3.ICP6810 and related instrument configuration

    Instrument host and necessary accessories
    order numberdefinitionSpecifications / modelsmanufacturerquantity remarksquantity remarks
    1Full-spectrum straight-read inductively coupled plasma emission spectrometerICP6810Shanghai Beauty Instrument Co., Ltd1 
    2Automatic temperature control and circulating cooling water device1 
    3stabilized voltage supply1 
    Instrument matching accessories
    order numberdefinitionSpecifications / modelsmanufacturerquantity remarksquantity remarks
    1host1 
    2graphoscope1 
    3marking punch1 
    Sample processing equipment and consumables
    order numberdefinitionSpecifications / modelsmanufacturerquantity remarksquantity remarks
    1Electronictemperature-controlled heating boardEG-35B1 
    2One in ten thousand is an electronic balanceBS224S1 
    3Laboratory-grade ultra-pure water machineEPED-40T1 
    4Disposable rubber GlovesM / 
    5Activated carbon mask  / 
    63mlpasteurpipette3ml / 
    7100mlglass beaker100mlSichuan Shu Glass scientific Instruments/ 
    8100mlGlass capacity bottle100mlSichuan Shu Glass scientific Instruments/ 
    95mltransfer liquid gun0.5ml-5mlRand, Germany1 
    101mltransfer liquid gun100ul-1000ulRand, Germany1 
    Reagent
    order numberdefinitionSpecifications / modelsmanufacturerquantity remarksquantity remarks
    1hydrochloric acid GR Jiangsu Qiangsheng Chemical Co., Ltdhydrochloric acid GR Jiangsu Qiangsheng Chemical Co., Ltdhydrochloric acid GR Jiangsu Qiangsheng Chemical Co., Ltd/ 
    2hydrogen nitrate GR Jiangsu Qiangsheng Chemical Co., Ltdhydrogen nitrate GR Jiangsu Qiangsheng Chemical Co., Ltdhydrogen nitrate GR Jiangsu Qiangsheng Chemical Co., Ltd/ 
    3perhydrol GR Jiangsu Qiangsheng Chemical Co., Ltdperhydrol GR Jiangsu Qiangsheng Chemical Co., Ltdperhydrol GR Jiangsu Qiangsheng Chemical Co., Ltd/
    4Standard material of each element 1000ug/ml National nonferrous Metals and electronic materials center of forecasting and analysisStandard material of each element 1000ug/ml National nonferrous Metals and electronic materials center of forecasting and analysisStandard material of each element 1000ug/ml National nonferrous Metals and electronic materials center of forecasting and analysis/ 
    Exhibition:


    The Company:

    The Factory:


    Contact Us:

    Quality Macy Lab Cid Detector Faster Detection Speed Medium Step Grating ICP-6810 for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Macylab Instruments Inc.
    *Subject:
    *Message: