Sign In | Join Free | My himfr.com
Home > Atomic Absorption Spectrophotometer >

Flame Atomic Absorption Spectrophotometer for Laboratory , Photometer

    Buy cheap Flame Atomic Absorption Spectrophotometer for Laboratory , Photometer from wholesalers
     
    Buy cheap Flame Atomic Absorption Spectrophotometer for Laboratory , Photometer from wholesalers
    • Buy cheap Flame Atomic Absorption Spectrophotometer for Laboratory , Photometer from wholesalers

    Flame Atomic Absorption Spectrophotometer for Laboratory , Photometer

    Ask Lasest Price
    Brand Name : Macy
    Model Number : AA-1800
    Certification : CE/ISO/ROHS
    Price : Negotiable
    Payment Terms : T/T,Western Union
    Supply Ability : 1000pcs/month
    Delivery Time : Received payment,within 10 days of delivery
    • Product Details
    • Company Profile

    Flame Atomic Absorption Spectrophotometer for Laboratory , Photometer

    Flame Atomic Absorption Spectrophotometer for Laboratory , Photometer


    Specifications:

    Mainframe

    Model:

    AA-1800

    Light Source:

    ≤6 lamps automatic turret, automatic alignment

    Power Supply:

    110/220V (+5% ~ -10%), 60/50Hz; 5000VA

    Lamp Current:

    pulsed power supply

    Optical System:

    large 1800 /mm grating ruling, full closed optical system

    Wavelength Range:

    180nm-900nm

    Automatically peak find,a key opticaloptimization function

    Wavelength Accuracy:

    ≤0.15nm

    Wavelength Repeatability:

    ±0.1nm

    Spectral Bandwidth:

    0nm,0.2nm,0.4nm,1.0nm,2.0nm

    (5 steps with automatic changeover)

    Baseline Stability:

    ≤±0.002A/30 min (Static)

    ≤±0.005A/30min (Dynamic)

    Absorbance Range:

    0-4A

    Detector:

    imported photomultiplier tube

    Flame Analytical System

    Burner Head:

    full titanium combustion head, 50mm or 100mm generalcombustion head

    Atomization Chamber:

    polymer explosion-proof spray chamber

    Nebulizer:

    atomizer efficient glass atomizer, can also be customized

    Ignition Type:

    microcomputer control, automatic ignition

    Gas Control:

    automatic gas control system

    Detection Limits(Cu):

    0.002μg/mL

    Precision:

    RSD≤0.5%

    Graphite Furnace Analytical System

    Heating Mode:

    vertical heating

    Temperature Control Method:

    vertical optical temperature monitoring graphite tube wall temperature

    Temperature Range:

    room temperature to 3000℃

    The Program:

    automatic temperature control up to 20 order

    Temperature Control:

    the furnace enriched up to 20 times

    Characteristics Volume:

    0.5 × 10-12g (Cd)

    Detection Limit:

    0.4 × 10-12g (Cd)

    Precision:

    RSD≤3%

    The Cooling Water:

    can choose cooling water circulation system

    Safety:

    the graphite tube damage, water flow

    air pressure and other alarmtemperature overheating protection

    Autosampler Graphite Furnace

    Sample Tray:

    70 sample cups, 6 reagent cup

    Sample Volume:

    1-100μl

    The Smallest Lincrement:

    0.1 μl

    The Volume of Sample

    better than 1%(at the time of 10mL-100mL)

    Repeatability Volume

    Repeated Sampling Frequency:

    up to 99 Times

    Cleaning and Waste

    each 500mL

    Container Volume


    Description:


    AA-1800 atomic absorption spectrophotometer is absorted the latest international technology and famous

    universities jointly complete R & D, application experience with decades of spectral instrument. The

    products include the flame , graphite furnace and hydride generation system, can be equipped with

    various accessories, flexible configuration program can meet different customer demand. AA-1800

    atomic absorption spectrometer can be used for analysis of complex samples ,full automatic

    multifunctional, various analysis methods can automatically switch, unmanned automatic analysis


    Applications:


    AA-1800 atomic absorption spectrophotometer is now widely used in scientific research,quality control,

    disease control, environmental protection, metallurgy, agriculture,chemical industry .Hardware and

    software design of innovation to ensure the accuracy,safety, ease of use in the analysis of samples,

    equipment maintenance, simple and convenient


    Competitive Advantage:


    High precision automatic optical system

    ● 1800 / mm reticle (dispersion rate) large area grating monochromator, a new type self collimation, all

    lenses are quartz coating, the detection range and the stability of optical broad to ensure the precision of

    analysis. Automatic 6 socket configuration six independent lamp power supply, can be respectively

    preheating

    Polymer spray chamber

    ● Polymer materials corrosion spray chamber, acid and alkali resistance, includinghydrofluoric acid, either

    organic or inorganic solution can be the highest sensitivity andstability

    Titanium burner

    ● Titanium burner, the optional 50mm and 100mm burner, air cooling pre mixed type,corrosion resistant,

    resistant to high salt, greatly improve the analysis efficiency andaccuracy of the flame

    Automatic analysis

    ● It can automatically accomplish safety ignition, extinction and switching, reliable structure,low fault rate, thus ensuring the sensitivity and reproducibility of the flame method.

    ● The light source system six lamp automatic conversion, can be directly used high performance hollow

    cathode lamp, improve the sensitivity analysis of the flame, the automatic adjustment of the power supply

    parameters and the beam position, automaticwavelength scanning and searching peak

    Software function

    ● High intelligent software, powerful function, friendly interface English operation.Automatic instruments

    and additional control, flame, graphite furnace operating mode can be switched automatically, automatic

    optimization, automatic dilution; mouse operation, automatic setup menu data and correction method

    Graphite furnace temperature control

    ● Gas dual temperature control inside and outside, 20 order linear or nonlinear heating, to ensure that

    the measured elements has the highest sensitivity; furnaceenriched up to 20 times, the longitudinal

    optically monitoring the graphite tube wall temperature, maximum temperature to 3000 degrees centigrade

    High technology index

    ● AA-1800 atomic absorption spectrophotometer elements testsensitivity meet international best

    level,sensitivity of less than or equal to0.015μg/mL/1%; baseline drift is less than 0.003Abs/30m, the

    stability is better than 0.005Abs/4h

    Background correction system

    ● Using deuterium hollow cathode lamp advanced and self absorption background deduction of

    background correction, to eliminate the interference of molecular absorption of low content determination,

    reducing the noise emission of deuterium lampand prolongs the service life, has excellent stability.

    Deuterium lamp background signalfor 1A, background correction ability > 50 times

    Intelligent analysis

    ● Greart intelligence, humanized design, flame and graphite furnace atomizer automatic switching,

    automatic optimization of graphite furnace atomizer, automatically set the flame height adjustment,

    automatic ignition, automatic optimization of the horizontal position, system automatically sets the gas flow.

    In the case of power failure, misoperation, acetylene leakage, the system will automatically start the

    safetyprotection function

    Automatic sampler

    ● Integrative design of graphite furnace, using high precision syringe, lowest in 0.5μl samples, with

    intelligent online dilution and concentration function

    Quality Flame Atomic Absorption Spectrophotometer for Laboratory , Photometer for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Macylab Instruments Inc.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)